Structural bolt capacities (AS 4100)
Design capacities of single M12 to M36 structural bolts to AS 4100:2020 in the bolting categories of Table 9.2.1: 4.6/S (AS 1111 or AS 1110 bolts), 8.8/S, 8.8/TB and 8.8/TF (AS/NZS 1252.1), and the 10.9 categories added in 2020, with ply bearing, hole sizes, pitch and edge distances.
Grade 4.6 and 8.8 bolts (one bolt, one shear plane)
| Bolt | 4.6/S (fuf = 400 MPa) | 8.8/S and 8.8/TB (fuf = 830 MPa, M12 800 MPa) | 8.8/TF friction | |||||
|---|---|---|---|---|---|---|---|---|
| φNtf (kN) | φVf N (kN) | φVf X (kN) | φNtf (kN) | φVf N (kN) | φVf X (kN) | Nti (kN) | φVsf (kN) | |
| M12 | 27.0 | 15.1 | 22.4 | 54.0 | 30.2 | 44.8 | – | – |
| M16 | 50.2 | 28.6 | 39.9 | 104.2 | 59.3 | 82.7 | 95 | 23.3 |
| M20 | 78.4 | 44.6 | 62.3 | 162.7 | 92.6 | 129.3 | 145 | 35.5 |
| M24 | 113.0 | 64.3 | 89.7 | 234.4 | 133.4 | 186.1 | 210 | 51.4 |
| M30 | 179.5 | 103.0 | 140.3 | 372.5 | 213.7 | 291.1 | 335 | 82.1 |
| M36 | 261.4 | 150.6 | 202.0 | 542.5 | 312.5 | 419.1 | 490 | 120.0 |
N: threads intercept the shear plane; X: they don't (plain shank). φVf is for one shear plane with kr = 1.0; multiply by the number of shear planes. φVsf is per effective interface with μ = 0.35 (clean as-rolled surfaces) and kh = 1.0 (standard holes). S: snug tight; TB and TF: fully tensioned (Table 9.2.1). Grade 8.8 bolts less than 16 mm in diameter (M12) have fuf = 800 MPa (Table 9.2.1, Note 2).
Grade 10.9 bolts (one bolt, one shear plane)
| Bolt | 10.9/S and 10.9/TB (fuf = 1040 MPa) | 10.9/TF friction | |||
|---|---|---|---|---|---|
| φNtf (kN) | φVf N (kN) | φVf X (kN) | Nti (kN) | φVsf (kN) | |
| M12 | 70.1 | 32.6 | 58.3 | – | – |
| M16 | 130.6 | 61.7 | 103.7 | 130 | 31.8 |
| M20 | 203.8 | 96.3 | 162.0 | 205 | 50.2 |
| M24 | 293.7 | 138.7 | 233.2 | 295 | 72.3 |
| M30 | 466.8 | 222.2 | 364.7 | 465 | 113.9 |
| M36 | 679.7 | 325.0 | 525.1 | 680 | 166.6 |
With threads intercepting the shear plane, grade 10.9 bolts take krd = 0.83 for their lower ductility (Cl. 9.2.2.1). Check availability and the Table 9.2.1 notes before specifying 10.9 bolts.
Ply in bearing
Design bearing capacity of the ply per millimetre of ply thickness, φVb/tp = 0.9 × 3.2dffup (kN/mm), for common ply tensile strengths fup (MPa):
| Bolt | 410 Grade 250 plate | 430 Grade 300 plate, C350L0 | 440 Grade 300 sections | 450 Grade 350 plate | 480 Grade 350 sections | 500 C450L0 |
|---|---|---|---|---|---|---|
| M12 | 14.2 | 14.9 | 15.2 | 15.6 | 16.6 | 17.3 |
| M16 | 18.9 | 19.8 | 20.3 | 20.7 | 22.1 | 23.0 |
| M20 | 23.6 | 24.8 | 25.3 | 25.9 | 27.6 | 28.8 |
| M24 | 28.3 | 29.7 | 30.4 | 31.1 | 33.2 | 34.6 |
| M30 | 35.4 | 37.2 | 38.0 | 38.9 | 41.5 | 43.2 |
| M36 | 42.5 | 44.6 | 45.6 | 46.7 | 49.8 | 51.8 |
Tear-out near an edge also limits the ply: φVp = 0.9aetpfup, where ae is the distance from the edge of the hole to the edge of the ply, measured in the direction of the force, plus half the bolt diameter (Cl. 9.2.2.4). Use the smaller of φVb and φVp.
Holes, pitch and edge distance (mm)
| Bolt | Standard hole | Oversize hole, max. | Short slot, max. length | Long slot, max. length | Min. pitch | Min. edge distance (Table 9.5.2) | ||
|---|---|---|---|---|---|---|---|---|
| Sheared or hand flame cut edge | Rolled plate, flat bar or section: machine cut, sawn or planed edge | Rolled edge of a rolled flat bar or section | ||||||
| M12 | 14 | 20 | 22 | 30 | 30 | 21 | 18 | 15 |
| M16 | 18 | 24 | 26 | 40 | 40 | 28 | 24 | 20 |
| M20 | 22 | 28 | 30 | 50 | 50 | 35 | 30 | 25 |
| M24 | 26 | 32 | 34 | 60 | 60 | 42 | 36 | 30 |
| M30 | 33 | 38 | 40 | 75 | 75 | 52.5 | 45 | 37.5 |
| M36 | 39 | 45 | 47.9 | 90 | 90 | 63 | 54 | 45 |
Hole sizes from Cl. 14.3.2: standard holes are df + 2 mm up to M24 and df + 3 mm above; oversize holes up to the larger of 1.25df and df + 8 mm; slots are the standard hole width, with short slots up to the larger of 1.33df and df + 10 mm long and long slots up to 2.5df. Oversize and slotted holes need hardened or plate washers, and Cl. 14.3.2 limits where they may be used. Base plate holes may be up to 6 mm larger than the anchor bolt, with a plate washer at least 4 mm thick where the hole is 3 mm or more oversize. Minimum pitch is 2.5df (Cl. 9.5.1). Edge distances are measured from the centre of a standard hole; for other holes, from the nearer edge of the hole plus df/2 (Cl. 9.5.2).
Bolt areas (AS 1275, mm²)
| Bolt | Thread pitch (mm) | Ao plain shank | As tensile stress | Ac minor diameter |
|---|---|---|---|---|
| M12 | 1.75 | 113 | 84.3 | 76.2 |
| M16 | 2 | 201 | 157 | 144 |
| M20 | 2.5 | 314 | 245 | 225 |
| M24 | 3 | 452 | 353 | 324 |
| M30 | 3.5 | 707 | 561 | 519 |
| M36 | 4 | 1018 | 817 | 759 |
Formulas (AS 4100:2020)
- Shear (Cl. 9.2.2.1): φVf = φ0.62fufkrdkr(nnAc + nxAo), φ = 0.8 (Table 3.4). krd = 1.0 except for 10.9 bolts with threads in the shear plane (0.83). kr = 1.0, or for a bolted lap connection of length lj 1.075 − lj/4000 between 300 and 1300 mm and 0.75 beyond (Table 9.2.2.1).
- Filler plates (Cl. 9.2.2.5): fillers more than 6 mm and less than 20 mm thick in total multiply Vf by 1 − 0.0154(t − 6), e.g. 0.908 for 12 mm.
- Tension (Cl. 9.2.2.2): φNtf = φAsfuf, φ = 0.8.
- Combined shear and tension (Cl. 9.2.2.3): (V*f/φVf)² + (N*tf/φNtf)² ≤ 1.0.
- Ply in bearing (Cl. 9.2.2.4): φVb = φ3.2dftpfup ≤ φaetpfup, φ = 0.9.
- Friction-type (8.8/TF, 10.9/TF) (Cl. 9.2.3): φVsf = φμneiNtikh, φ = 0.7 (Cl. 3.5.5), with Nti from Table 15.2.2.2, μ = 0.35 for clean as-rolled contact surfaces and kh = 1.0 for standard holes, 0.85 for short slotted and oversize holes and 0.70 for long slotted holes. It limits slip at the serviceability limit state; the bolts must also be checked at the strength limit state (Cl. 9.2.2).
Design aid only, not a substitute for a qualified engineer or for AS 4100 itself. See the disclaimer and data sources.