Free Australian steel section data · AS 4100 · AS/NZS 3679 · AS/NZS 1163 DownloadsAdvertiseContact

48.3x2.9CHS Circular Hollow Section

AS/NZS 1163Grade C350L0

The 48.3x2.9CHS is a circular hollow section to AS/NZS 1163. It is 48.3 mm outside diameter with a 2.9 mm wall, has a mass of 3.25 kg/m and a gross area of 414 mm². Its major-axis second moment of area is Ix = 0.107 × 10⁶ mm⁴ and in Grade C350L0 (fy = 350 MPa) its section moment capacity is φMsx = 1.9 kNm. Download its free DXF drawing (a true-scale CAD outline) below, or print the dimensioned drawing sheet.

Also written as: 48.3 x 2.9 CHS, 48.3x2.9 CHS

DXF (AutoCAD R12)SVG drawingJSON data
48.3x2.9CHS Circular Hollow Section cross-section drawingdo = 48.3xxyyt = 2.9NOTES1. ALL DIMENSIONS IN MILLIMETRES. TRUE SCALE 2:1 WHEN PRINTED ON A4.2. x-x, y-y: CENTROIDAL (PRINCIPAL) AXES.3. VERIFY AGAINST MANUFACTURER DATA BEFORE USE.STEELINFOSTEELINFO.AUTITLE48.3x2.9CHS CIRCULAR HOLLOW SECTIONSTANDARDAS/NZS 1163GRADEC350L0SCALE @ A42:1UNITSmmDATE2026-10-08

Open the drawing full size (pinch to zoom)

Dimensions

48.3x2.9CHS dimensions
SymbolPropertyValueUnit
doOutside diameter48.3mm
tWall thickness2.9mm
diInside diameter42.5mm

Section properties

48.3x2.9CHS section properties
SymbolPropertyValueUnit
mMass per metre (nominal)3.25kg/m
AgGross cross-section area414mm²
IxSecond moment of area about x-axis0.10710⁶ mm⁴
ZxElastic section modulus, x-axis4.4310³ mm³
SxPlastic section modulus, x-axis5.9910³ mm³
rxRadius of gyration, x-axis16.1mm
IySecond moment of area about y-axis0.10710⁶ mm⁴
ZyElastic section modulus, y-axis4.4310³ mm³
SyPlastic section modulus, y-axis5.9910³ mm³
ryRadius of gyration, y-axis16.1mm
JTorsion constant21410³ mm⁴
CTorsion modulus8.8610³ mm³
AsExternal surface area per metre0.152m²/m
As/tExternal surface area per tonne46.7m²/t

Axes: x-x is the major axis and y-y the minor axis, both through the centroid.

Mass 19.5 kg · surface area 0.91 m²

Design capacities to AS 4100

AS 4100 design capacities – Grade C350L0
SymbolPropertyValueUnit
Steel gradeC350L0 (AS/NZS 1163)
fyYield stress used350MPa
fuTensile strength430MPa
kfForm factor (Cl. 6.2.2)1.000
Section class, x-axis (Cl. 5.2)Compact
ZexEffective section modulus, x-axis5.9910³ mm³
φMsxSection moment capacity, x-axis1.9kNm
Section class, y-axisCompact
ZeyEffective section modulus, y-axis5.9910³ mm³
φMsySection moment capacity, y-axis1.9kNm
φNsSection compression capacity (Cl. 6.2.1)130kN
φNtTension capacity, gross section (Cl. 7.2, kt=1, An=Ag)130kN
φVvShear capacity (Cl. 5.11)47kN
αbCompression member section constant (Table 6.3.3)-0.5
Member capacity vs effective length (αm = 1.0)
Le (m)φNcx (kN)φNcy (kN)
0.5124124
1103103
1.568.568.5
242.642.6
2.528.228.2
319.919.9
3.514.814.8
411.411.4
57.47.4
65.25.2
73.83.8
82.92.9
92.32.3
101.91.9
121.31.3

φNc: Cl. 6.3.3, pin-ended effective length Le = keL, concentric load.

1341078053270024681012Effective length Le (m)
φNcx (kN)φNcy (kN)
Member capacity calculator

Check it for a span and loads with the beam calculator.

For restraint types, ktklkr and αm, use the lateral restraint calculator.

Instant check only. Effective lengths and moment modification factors must be determined by the designer in accordance with AS 4100 Cl. 4.6, 5.6.3 and 6.3.2. Not a substitute for a qualified engineer: see the disclaimer.

Alternatives with similar bending capacity

Sections from other families with a plastic modulus Sx within −8% / +25% of the 48.3x2.9CHS, lightest first.

SectionTypeMass (kg/m)Sx (10³ mm³)Ix (10⁶ mm⁴)
75x25x1.6RHSRectangular Hollow Section2.386.810.197
50x50x2.0SHSSquare Hollow Section2.936.660.141
50x25x3.0RHSRectangular Hollow Section3.075.860.112
40x40x3.0SHSSquare Hollow Section3.305.720.0932
40x40x4.0SHSSquare Hollow Section4.096.740.105

Other circular hollow sections

Relevant Australian Standards

See all Australian Standards for structural steel.

Properties are calculated from nominal dimensions, including root and toe radii, as described in notation & method. Mass is the nominal catalogue mass; the calculated mass at 7850 kg/m³ is 3.25 kg/m. Verify against current manufacturer literature before use in design. Spotted an error? Report it.